PLC → AASX · screen recording · 48 seconds

From a PLC program to AAS (AASX), start to finish

Upload one PLC project file and the converter reads the program structure and I/O signals, arranges them into a process-model table and exports an AAS package (.aasx). The video shows the whole run on an LS XGK project file.

48 seconds · no sound · on-screen text is in KoreanOpen the video file

Five scenes in the video

Click a time to play from that scene. The numbers are the values shown on screen.

  1. Choose the vendor and the file

    LS ELECTRIC (XG5000) is selected as the PLC vendor and a project file (.xgwx) is uploaded. The other vendors on screen are marked as in development.

  2. Six analysis stages

    File check → device identification → circuit analysis → signal classification → AI processing → result summary. A dialog asks once to confirm the flow groups. The waiting part is shown at 8× speed.

  3. Analysis summary

    The summary shows 10 program units (POUs), 4,057 tags, an analysis time of 31.5 seconds and 3 parsing warnings, and the AASX file is generated.

  4. Check the result: ladder, tag table, DS2 table

    The ladder is redrawn per POU. The tag table marks inputs as Observe and outputs as Command, and the DS2 table lines up Flow, Work, Device and API with their input and output addresses.

  5. Export the AASX

    Set the identifier prefix (IRI Prefix) and download the .aasx file.

What the converter does, and what people do

01

It reads the program

It extracts program units (POUs), ladder circuits, tags and addresses from the PLC project file.

02

It arranges a process-model table

Actions are grouped by output signal and matched with their input and output addresses. Anything it cannot match stays visible as a warning or a “missing” mark.

03

People review and complete it

The result is a draft. Check the warnings and add what a program does not contain, such as nameplate and connection data, to get a complete AAS.

Questions and answers

Which PLC files does it convert?

The converter in the video reads LS ELECTRIC XG5000 project files (.xgwx). Other vendors are marked as in development on screen.

Can I try it myself now?

The converter will be released again in a new version. Until then, send us what you have and DualSoft converts, reviews and delivers the AAS package as the on-site AAS creation service.

What is in the result?

As shown in the video: the ladder per program unit, a tag table, and the DS2 table that lines up Flow, Work, Device and API with input and output addresses. All of it downloads as one AAS package (.aasx).

Can I use the result as it is?

Treat it as a draft. The video itself shows parsing warnings. Check them and fill in nameplate and connection data, which a program does not contain, before using it.

What are AAS and AASX?

The Asset Administration Shell (AAS) is a standard digital representation of an asset such as a machine or a product; AASX is the package format that bundles it into one file. The AAS practical guide below explains both.

Is there no sound?

Correct. It is a silent screen recording with Korean on-screen text. The scene list on this page describes each part.

Want an AAS built from your own PLC?

Tell us which equipment needs an AAS, your PLC make and model, and what you have (program files, operation logs, equipment documents).